(C) Motor constant parameters
Pr.
744
C207
745
C208
463
C210
458
C220
460
C222
461
C223
860
C226
738
C230
739
C231
740
C232
741
C282
742
C285
746
C233
For FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, it is set to 85% of the
inverter rated current.
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
Differs according to the voltage class. (200 V/400 V)
The setting range and unit change according to the Pr. 71 (Pr. 450) setting.
5 - 456
Name
Second motor inertia
(integer)
Second motor inertia
(exponent)
Second motor auto tuning
setting/status
Second motor constant (R1)
Second motor constant (L1) /
d-shaft inductance (Ld)
Second motor constant (L2) /
q-shaft inductance (Lq)
Second motor torque current/
Rated PM motor current
Second motor induced
voltage constant (phi f)
Second motor Ld decay ratio
Second motor Lq decay ratio
Second starting resistance
tuning compensation
Second motor magnetic pole
detection pulse width
Second motor protection
current level
Initial
Setting range
value
9999
10 to 999, 9999
9999
0 to 7, 9999
0, 101
1
0
11
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 mH, 9999
9999
0 to 50 mH, 9999
0 to 500 A, 9999
9999
0 to 3600 A, 9999
0 to 5000 mV/(rad/s)
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs,
9999
10000 to 16000 μs, 9999
100 to 500%
9999
9999
Parameters
Description
Set the inertia of the second motor.
9999: Uses MM-CF inertia for IPM
motor MM-CF.
No auto tuning for the second motor.
Performs offline auto tuning without
rotating the second motor. (motor
other than the IPM motor MM-CF)
Performs offline auto tuning without
rotating the motor (for IPM motor
MM-CF).
Tuning data of the second motor
(The value measured by offline auto
tuning is automatically set.)
9999: Uses the MM-CF constant for
the IPM motor MM-CF, and the
inverter internal data for a PM motor
other than MM-CF.
Set this parameter according to the
PM motor specifications.
Value calculated based on the tuning
data.
Tuning data of the second motor.
(The value measured by offline auto
9999: Uses the MM-CF constant for
the IPM motor MM-CF, and the
inverter internal data for a PM motor
other than MM-CF.
Set the maximum current (OCT) level
of the second motor.
Uses the MM-CF constant for the IPM
motor MM-CF, and 200% for a PM
motor other than MM-CF.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents