Parameters
Types of monitor
Torque monitor (power
driving/regenerative
driving polarity
switching)
Motor temperature
Energy saving effect
PID set point
PID measured value
PID deviation
Motor thermal load
factor
Inverter thermal load
factor
PID measured value 2
PLC function analog
output
Remote output value 1
Remote output value 2
Remote output value 3
Remote output value 4
PID manipulated
variable
Second PID set point
Second PID measured
value
Second PID deviation
Second PID measured
value 2
Second PID manipulated
variable
Dancer main speed
setting
Control circuit
temperature
Tab. 5-135: Monitor description list (2)
Differs according to capacities. (FR-A820-03160(55K) or lower, FR-A840-01800(55K) or lower/
FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher)
When the output current is less than the specified current level (5% of the rated inverter current),
the output current is monitored as 0 A. Therefore, the monitored value of an output current and
output power may be displayed as "0" when using a much smaller-capacity motor compared to
the inverter or in other instances that cause the output current to fall below the specified value.
Setting of Pr. 1018 "Monitor with sign selection" is required.
The setting is available only for standard models.
The setting is available only with terminal AM (Pr. 158).
FR-A800
Pr. 54
(FM/CA)
Unit
Pr. 158 (AM)
setting
0.1 %
36
1 °C
46
Changeable
by parameter
50
setting
0.1%
52
0.1%
53
0.1%
54
0.1%
61
0.1%
62
0.1%
67
0.1%
70
0.1%
87
0.1%
88
0.1%
89
0.1%
90
0.1%
91
0.1%
92
0.1%
93
0.1%
94
0.1%
95
0.1%
96
0.01 Hz
97
1 °C
98
(M) Monitor display and monitor output signal
Terminal
Negative
FM, CA, AM
(-) output
Full-scale value
Pr. 866
Pr. 751
Inverter capacity
100%
100%
100%
Motor thermal
operation level
(100%)
Inverter thermal
operation level
(100%)
100%
100%
100%
100%
100%
100%
100%
100%
100%
200%
100%
100%
Pr. 55
100 °C
Remarks
Enabled when the FR-A8AZ
is used.
Regarding the energy
saving monitor, refer to
page 5-189
Refer to page 5-537 for the
PID control.
Output with a negative sign
(terminal AM)
Refer to page 5-587 for the
PLC function.
Refer to page 5-382 for the
analog remote output.
Output with a minus sign
(terminal AM)
Refer to page 5-537 for the
PID control.
Refer to page 5-552 for the
dancer control.
Terminal FM/CA: 0 to 100°C
Terminal AM: -20 to 100°C
5 - 343