Easy operation mode setting (easy setting mode)
NOTES
Pr. 79 may not be included in the user group set by Pr. 160 "User group read selection" = "1".
Setting cannot be changed during operation. Turn the start command (FWD or REV key, STF or
STR) OFF.
If the MODE key is pressed before pressing the SET key, the easy setting mode is terminated and
the display goes back to the monitor display. If the easy setting mode is terminated while Pr. 79 =
"0 (initial value)", the operation mode switches between the PU operation mode and the External
operation mode. Check the operation mode.
Reset by STOP/RESET key is enabled.
The priorities of the frequency commands when Pr. 79 = "3" are "Multi-speed operation (RL/RM/
RH/REX) > PID control (X14) > terminal 4 analog input (AU) > digital input from the operation
panel".