Mitsubishi Electric FR-A820-00046 Instruction Manual page 720

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

(A) Application parameters
Setting multiple PID functions
● When the second PID function is set, two sets of PID functions can be switched for use. The PID
setting is selected as shown in the table below.
Pr.128 setting
(First PID setting)
"0" or not applied to the
frequency
"0" or not applied to the
frequency
Applied to the frequency
Applied to the frequency
Dancer control
Tab. 5-227: Selection of PID settings
While Pr. 155 = "0", the second function is enabled immediately after RT signal turns ON. While
Pr. 155 = "10", the second function is enabled only during constant speed operation when RT signal
turns ON.
When dancer control is selected, the setting is not applied to the frequency.
5 - 540
Pr. 753 setting
(Second PID setting)
"0" or not applied to the
frequency
Applied to the frequency
"0" or not applied to the
frequency
Applied to the frequency
Not applied to the frequency
Pr.155
PID setting applied to the
RT signal
output frequency
setting
Control other than PID
control
Second PID setting
First PID setting
OFF
First PID setting
0
ON
Second PID setting
10
First PID setting
Dancer control
Parameters

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents