Position control under vector control and PM sensorless vector control
5.5.6

Pulse monitor

Various pulses can be monitored.
Pr.
430
B011
635
M610
636
M611
637
M612
638
M613
The setting is available when a vector control compatible option is installed.
Pulse monitor selection (Pr. 430)
● Shows the various pulse conditions during operation as the number of pulses.Set "0" in Pr. 52
"Operation panel main monitor selection" to display the output frequency monitor.
● If any of "26 to 31" is set in Pr. 52, Pr. 774 to Pr. 776, and Pr. 992, the electronic gear operation setting
for the pulse monitor by the multifunction monitor can be changed. (Refer to page 5-327.)
Pr. 430 Setting
0
1
Tab. 5-62:
5 - 172
Vector
Vector
Vector
PM
PM
PM
Name
Pulse monitor selection
Cumulative pulse clear
signal selection
Cumulative pulse division
scaling factor
Control terminal option-
Cumulative pulse division
scaling factor
Cumulative pulse storage
0
1
2
3
Pulse monitor
selection
4
5
12
13
For pulse monitor
selection
Pulse monitor selection (1)
Initial
Setting
Description
value
range
0 to 5, 12, 13,
100 to 105,
112, 113,
1000 to
Shows the various pulse conditions during operation
1005, 1012,
as the number of pulses.
9999
1013, 1100
to 1105,
1112, 1113
8888, 9999
Shows the frequency monitor.
Select the clearing method for the cumulative pulse
0
0 to 3
monitor.
Set the division scaling factor on the cumulative pulse
1
1 to 16384
for the plug-in option (FR-A8AP).
Set the division scaling factor on the cumulative pulse
1
1 to 16384
for the control terminal option (FR-A8TP).
Select the processing method for the cumulative
0
0 to 3
pulse monitor value when the power is turned OFF or
the inverter is reset.
Description
Displays the lower of the position command (accumulated value of command
pulses).
Displays the upper of the position command (accumulated value of command
pulses).
Displays the lower of the current position (accumulated value of feedback
pulses ).
Displays the upper of the current position (accumulated value of feedback
pulses ).
Displays the lower of the accumulated value of droop pulses.
Displays the upper of the accumulated value of droop pulses.
Displays the lower of the current position 2 (accumulated value of feedback
pulses )
Displays the upper of the current position 2 (accumulated value of feedback
pulses )
Displays the monitor item selected in the pulse monitor selection after the
electronic gear operation.
Displays the monitor item selected in the pulse monitor selection before the
electronic gear operation.
Parameters

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents