Copying and verifying parameters using USB memory

5.19
Copying and verifying parameters using USB memory
● Inverter parameter settings can be copied to USB memory.
● Parameter setting data copied to USB memory can be copied to other inverters or verified to see
if they differ from the parameter settings of other inverters.
● Parameter settings can also be imported to a personal computer and edited in FR Configurator2.
Changes in USB memory copy operation states
Insert the USB memory in the inverter. The USB memory mode is displayed and USB memory opera-
tions are possible.
Monitor mode
USB memory mode
Parameter setting
file number saved in
the USB memory
device (up to 99)
Fig. 5-351:
Changes in USB memory copy operation states
5 - 704
Function mode
Parameter setting mode
Faults history mode
Copy the parameter setting
from the inverter to the USB
memory device.
Overwrite the inverter parameter setting onto the
designated file in the USB memory device.
Parameters
Write the designated
parameter setting file of
the USB memory device
to a parameter file of the
inverter.
Verify the designated
parameter setting file of
the USB memory device
against the parameter file
of the inverter.