Mitsubishi Electric FR-A820-00046 Instruction Manual page 948

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Measurement of main circuit voltages, currents and powers
Item
Fault signal
Tab. 7-5:
Use an FFT to measure the output voltage accurately. A tester or general measuring instrument
cannot measure accurately.
When the carrier frequency exceeds 5 kHz, do not use this instrument since using it may increase
eddy current losses produced in metal parts inside the instrument, leading to burnout. In this case,
use an approximate-effective value type.
When the setting of Pr. 195 "ABC1 terminal function selection" is the positive logic
A digital power meter (designed for inverter) can also be used to measure.
7 - 14
Measuring point
Measuring instrument
Across A1 and C1
Moving-coil type
(such as tester)
Across B1 and C1
Measuring Points and Instruments (2)
Precautions for maintenance and inspection
Remarks (reference measured value)
Continuity check
[Normal]
Across A1 and C1 Discontinuity Continuity
Across B1 and C1 Continuity
[Fault]
Discontinuity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents