Parameters
Setting the frequency during stop-on-contact control (Pr. 270 = "1, 3, 11 or 13")
● The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are
selected together. Grey shaded fields indicate stop-on-contact control is valid.
● Stop-on-contact control is disabled when remote setting function is selected (Pr. 59 = "1 to 3").
RH
RM
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
Tab. 5-208: Frequency and combined input signals
NOTE
Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may
affect the other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 4 to Pr. 6,
Pr. 24 to Pr. 27
Pr. 15
Pr. 22
Pr. 48
Pr. 22
Pr. 59
Pr. 72
Pr. 79
Pr. 95
Pr. 128
Pr. 178 to Pr. 189
Pr. 270
Pr. 292
FR-A800
Input signal
Set frequency
RL
RT
JOG
Pr. 4 "Multi-speed setting
(high speed)"
Pr. 5 "Multi-speed setting
(middle speed)"
Pr. 6 "Multi-speed setting
ON
(low speed)"
By 0 to 5 V (0 to 10 V), 4 to
ON
20 mA input
ON Pr. 15 "Jog frequency"
Pr. 26 "Multi-speed setting
(speed 6)"
Pr. 25 "Multi-speed setting
ON
(speed 5)"
Pr. 4 "Multi-speed setting
ON
(high speed)"
ON Pr. 15 "Jog frequency"
Pr. 24 "Multi-speed setting
ON
(speed 4)"
Pr. 5 "Multi-speed setting
ON
(middle speed)"
ON Pr. 15 "Jog frequency"
Pr. 6 "Multi-speed setting
ON
ON
(low speed)"
ON
ON Pr. 15 "Jog frequency"
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON Pr. 15 "Jog frequency"
(multi-speed setting)
Jog frequency
Stall prevention operation level
Second stall prevention operation level
Torque limit level
Remote function selection
PWM frequency selection
Operation mode selection
Online auto tuning selection
PID action selection
(input terminal function selection)
Stop-on contact/load torque high-speed frequency control
selection
Automatic acceleration/deceleration
(A) Application parameters
Input signal
RH
RM
RL
RT
JOG
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON Pr. 15 "Jog frequency"
ON
ON
ON
ON
ON
ON
ON
ON
ON Pr. 15 "Jog frequency"
=>
=>
=>
=>
=>
=>
=>
=>
=>
=>
=>
=>
=>
Set frequency
Pr. 6 "Multi-speed setting
(low speed)"
Pr. 6 "Multi-speed setting
(low speed)"
Pr. 26 "Multi-speed setting
(speed 6)"
Pr. 27 "Multi-speed setting
(speed 7)"
Pr. 6 "Multi-speed setting
(low speed)"
By 0 to 5 V (0 to 10 V),
4 to 20 mA input
page 5-189
page 5-286
page 5-84
page 5-84
page 5-84
page 5-247
page 5-219
page 5-263
page 5-465
page 5-524
page 5-422
page 5-494
page 5-255, page 5-260
5 - 493