Parameters
Types of
monitor
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
Option input
terminal status 1
(for
communication)
Option input
terminal status 2
(for communica-
tion)
Option output
terminal status 1
(for communica-
tion)
Motor thermal
load factor
Inverter thermal
load factor
PTC thermistor
resistance
PID measured
value 2
Cumulative
pulse
Cumulative
pulse overflow
times
Cumulative
pulse (control
terminal option)
Tab. 5-126: Monitor description list (4)
FR-A800
Pr. 52,
Unit
Pr. 774 to Pr. 776,
Pr. 992
55
56
57
0.1%
61
0.1%
62
0.01 kΩ
64
0.1%
67
71
72
73
(M) Monitor display and monitor output signal
RS-485
communica-
MODBUS
tion dedicat-
RTU real
Minus (-)
ed monitor
time
display
(hexadeci-
monitor
mal)
H0F
40215
H10
40216
H3A
40258
H3B
40259
H3C
40260
H3D
40261
H3E
40262
H40
40264
H43
40267
H47
40271
H48
40272
H49
40273
Description
Displays input terminal ON/OFF
state of the inverter. (Refer to
page 5-336 for DU display.)
Displays output terminal ON/OFF
state of the inverter. (Refer to
page 5-336 for DU display.)
Displays input terminal ON/OFF
state of the digital input option
(FR-A8AX) on the DU.
(Refer to page 5-336 for details.)
Displays output terminal ON/OFF
state of the digital output option
(FR-A8AY) and the relay output
option (FR-A8AR) on the DU.
(Refer to page 5-336 for details.)
Input terminal X0 to X15 ON/OFF
state of the digital input option
(FR-A8AX) can be monitored via
RS-485 communication and the
communication option.
Input terminal DY ON/OFF state
of the digital input option
(FR-A8AX) can be monitored via
RS-485 communication and the
communication option.
Output terminal ON/OFF state of
the digital output option
(FR-A8AY) and relay output
option (FR-A8AR) can be
monitored via RS-485
communication and the
communication option.
Displays the accumulated heat
value of the motor thermal O/L
relay.
The motor overload trip (E.THM)
occurs at 100%.
Displays the accumulated heat
value of the inverter thermal O/L
relay.
The inverter overload trip (E.THT)
occurs at 100%.
Displays the PTC thermistor
resistance when Pr. 561 "PTC
thermistor protection level" ≠
9999 (voltage monitor when
Pr. 561 = 9999).
Displays the PID control
measured value even if PID
control operating conditions are
not satisfied while the PID
control is enabled (Pr.128 ≠ "0").
(Refer to page 5-537)
The cumulative number of
pulses is displayed (monitor
range: –32767 to 32767)
(for FR-A8AP/FR-A8APR).
The number of the cumulative
pulse carrying-over times is
displayed (for FRA8AP/
FR-A8APR).
The cumulative number of
pulses is displayed (monitor
range: –32767 to 32767)
(for FR-A8TP).
5 - 331