A.1.2
Replacement of the FR-A500(L) series
Installation precautions
● Installation size is compatible for replacing the FR-A520(L)-0.4K to 90K, FR-A540(L)-0.4K to 7.5K,
18.5K to 55K, 110K, 160K, or 220K. New mounting holes are required for replacing models with
other capacities.
● To use the same mounting holes of the FR-A540-11K or 15K for the A800 series, the optional
installation interchange attachment (FR-AAT) is necessary.
● The heatsink protrusion attachment is not interchangeable.
The enclosure cut dimensions of the FR-A520-3.7K or lower, FR-A520-30K, FR-A520-55K or higher,
FR-A540-3.7K or lower, FR-A540-11K and 15K, and FR-A540-75K or higher are not compatible.
NOTE
For the installation size and the outline dimensions of the separated converter type, refer to the
FR-A802 (Separated Converter Type) Instruction Manual (Hardware).
FR-A800
For customers replacing the conventional model with this inverter