(M) Monitor display and monitor output signal
5.11.11

Analog remote output function

An analog value can be output from the analog output terminal.
Pr.
655
M530
656
M531
657
M532
658
M533
659
M534
Analog remote output (Pr. 656 to Pr. 659)
● The terminals FM/CA, AM and the analog output terminal of the option FR-A8AY can output the
values set in Pr. 656 to Pr. 659 (Analog remote output).
● When Pr. 54 "FM/CA terminal function selection" = "87, 88, 89, or 90" (remote output), the FM type
inverter can output a pulse train from the terminal FM.
● For FM output (Pr. 291 "Pulse train I/O selection" = "0 (initial value) or 1"):
Terminal FM output [pulses/s] = 1440 [Hz] × (analog remote output value – 1000)/100
Where the output range is 0 to 2400 pulses/s.
● For high-speed pulse output (Pr. 291 "Pulse train I/O selection" = "10, 11, 20, or 21"):
Terminal FM output [pulses/s] = 50K [Hz] × (analog remote output value – 1000)/100
Where the output range is 0 to 55K pulses/s.
800
Fig. 5-180:
5 - 382
Initial
Name
value
Analog remote
0
output selection
Analog remote
1000%
output 1
Analog remote
1000%
output 2
Analog remote
1000%
output 3
Analog remote
1000%
output 4
Pulse speed
[pulse/s]
2400
1440
0
1000
1100
Analog remote output value [%]
Terminal FM (FM output)
Terminal FM output
Setting
Description
range
Remote output data is cleared when the
0
power supply is turned OFF
Remote output data is retained when
1
the power supply is turned OFF
Remote output data is cleared when the
10
power supply is turned OFF
Remote output data is retained when
11
the power supply is turned OFF
Value output from the terminal set as
800 to
"87" in terminal function selection
1200%
(Pr. 54, Pr. 158)
Value output from the terminal set as
800 to
"88" in terminal function selection
1200%
(Pr. 54, Pr. 158)
Value output from the terminal set as
800 to
"89" in terminal function selection
1200%
(Pr. 54, Pr. 158)
Value output from the terminal set as
800 to
"90" in terminal function selection
1200%
(Pr. 54, Pr. 158)
1200
800
Terminal FM (High-speed pulse train output)
Remote output data is
cleared during an inverter
reset
Remote output data is
retained during an
inverter reset
Set the analog value for
outputting from the
analog output terminals
FM/CA and AM and option
FR-A8AY.
Pulse speed
[pulse/s]
55K
50K
0
1000
1100
Analog remote output value [%]