Mitsubishi Electric FR-A820-00046 Instruction Manual page 254

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Control method
Pr.
Name
Pr. 998
Frequency for maximum
386
input pulse
505
Speed setting reference
Current average value
557
monitor signal output
reference current
820
Speed control P gain 1
Speed control integral
821
time 1
Torque control P gain 1
824
(current loop proportional
gain)
Torque control integral time
825
1 (current loop integral
time)
870
Speed detection hysteresis
Regeneration avoidance
885
compensation frequency
limit value
Energy saving monitor
893
reference (motor capacity)
C14
Terminal 1 gain frequency
(918)
(speed)
Per-unit speed control
1121
reference frequency
⎯: Not changed
Tab. 5-27:
IPM parameter initialization list (2)
Initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
Initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) and higher.
Setting Pr. 71 "Applied motor" = "333, 334, 8093, 8094, 9093, or 9094" does not change the Pr. 71
setting.
When a value other than "9999" is set, the set value is not changed.
200 r/min when Pr. 788 "Low speed range torque characteristic selection" = "0".
13.33 Hz when Pr. 788 "Low speed range torque characteristic selection" = "0".
110% for SLD, 120% for LD, 150% for ND, and 200% for HD
(Refer to Pr. 570 "Multiple rating setting" page 5-201.)
The Pr. 702 "Maximum motor frequency" is used as the maximum motor frequency. When Pr. 702 =
"9999 (initial value)", the Pr. 84 "Rated motor frequency" is used as the maximum motor frequency.
NOTE
If IPM parameter initialization is performed in rotations per minute (Pr. 998 = "3003, 8009, or
9009"), the parameters not listed in the table and the monitored items are also set and displayed
in rotations per minute.
5 - 74
Induction
PM motor
motor
(rotations per minute)
0
(initial value)
3003
(MM-CF)
FM
CA
60 Hz
50 Hz
2000 r/min
60 Hz
50 Hz
133.33 Hz
Rated motor
Rated inverter
current
current
(Refer to
page 8-8.)
60%
0.333 s
100%
5 ms
0 Hz
8 r/min
6 Hz
200 r/min
Rated inverter
capacity
60 Hz
50 Hz
2000 r/min
120 Hz
60 Hz
Setting
PM motor (frequency)
8009
9009
3103
(other than
(MM-CF)
MM-CF)
Pr. 84
133.33 Hz
Pr. 84
133.33 Hz
Rated motor
current
Pr. 859
(Refer to
page 8-8.)
30%
0.333 s
100%
20 ms
0.5 Hz
Pr. 84 × 10%
13.33 Hz
Motor capacity (Pr. 80)
Pr. 84
133.33 Hz
Maximum
motor
200 Hz
frequency
Parameters
Setting increments
8109
3003,
0, 3103,
9109
8009,
(other than
9009
MM-CF)
Pr. 84
1 r/min
0.01 Hz
Pr. 84
0.01 Hz
0.01 A
Pr. 859
0.1 A
1%
0.001 s
1%
0.1 ms
1 r/min
0.01 Hz
Pr. 84 × 10%
1 r/min
0.01 Hz
0.01 kW
0.1 kW
Pr. 84
1 r/min
0.01 Hz
Maximum
motor
1 r/min
0.01 Hz
frequency
8109,
9109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents