Mitsubishi Electric FR-A820-00046 Instruction Manual page 184

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameter List
Pr.
Pr.
Name
group
44
F020
Second acceleration/deceleration time
45
F021
Second deceleration time
46
G010
Second torque boost
47
G011
Second V/F (base frequency)
48
H600
Second stall prevention operation level
Second stall prevention operation
49
H601
frequency
50
M444
Second output frequency detection
H010
Second electronic thermal O/L relay
51
C203
Rated second motor current
Operation panel main monitor
52
M100
selection
54
M300
FM/CA terminal function selection
55
M040
Frequency monitoring reference
56
M041
Current monitoring reference
57
A702
Restart coasting time
58
A703
Restart cushion time
59
F101
Remote function selection
60
G030
Energy saving control selection
61
F510
Reference current
62
F511
Reference value at acceleration
63
F512
Reference value at deceleration
64
F520
Starting frequency for elevator mode
65
H300
Retry selection
Stall prevention operation reduction
66
H611
starting frequency
67
H301
Number of retries at fault occurrence
68
H302
Retry waiting time
69
H303
Retry count display erase
G107
Special regenerative brake duty
70
71
C100
Applied motor
Tab. 5-2:
Parameter overview (by number) (3)
5 - 4
Minimum
Setting range
setting
increments
0 to 3600 s
0 to 3600 s, 9999
0 to 30%, 9999
0 to 590 Hz, 9999
0.01 Hz
0 to 400%
0 to 590 Hz, 9999
0.01 Hz
0 to 590 Hz
0.01 Hz
0.01 A
0 to 500 A, 9999
0 to 3600 A, 9999
0, 5 to 14, 17 to 20,
22 to 36, 38, 40 to 46, 50
to 57, 61, 62, 64, 67, 71 to
74, 87 to 98, 100
1 to 3, 5 to 14, 17, 18, 21,
24, 32 to 34, 36, 46, 50,
52, 53, 61, 62, 67, 70, 87
to 90, 92, 93, 95, 97, 98
0 to 590 Hz
0.01 Hz
0.01 A
0 to 500 A
0 to 3600 A
0, 0.1 to 30 s, 9999
0 to 60 s
0 to 3, 11 to 13
0, 4, 9
0 to 500 A, 9999
0.01 A
0 to 3600 A, 9999
0.1 A
0 to 400%, 9999
0 to 400%, 9999
0 to 10 Hz, 9999
0.01 Hz
0 to 5
0 to 590 Hz
0.01 Hz
0 to 10, 101 to 110
0.1 to 600 s
0
0 to 100%
0 to 6, 13 to 16, 20, 23, 24,
30, 33, 34, 40, 43, 44, 50,
53, 54, 70, 73, 74, 330,
333, 334, 8090, 8093,
8094, 9090, 9093, 9094
Initial value
Refer
to page
FM
CA
5-233,
0.1 s
5 s
5-552
5-233,
0.1 s
9999
5-552
0.1%
9999
5-652
9999
5-654
0.1%
150%
5-314
0 Hz
5-314
30 Hz
5-373
5-292,
9999
5-67,
0.1 A
5-454
1
0
5-327
1
1
5-341
60 Hz
50 Hz
5-341
Rated inverter
5-341
current
0.1 A
5-562,
0.1 s
9999
5-571
0.1 s
1 s
5-562
1
0
5-247
1
0
5-659
5-255,
9999
5-260
0.1%
9999
5-255
0.1%
9999
5-255
9999
5-260
1
0
5-307
60 Hz
50 Hz
5-84
1
0
5-307
0.1 s
1 s
5-307
1
0
5-307
0.1%
0%
5-675
5-434,
1
0
5-440
5-454
Parameters

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents