Mitsubishi Electric FR-A820-00046 Instruction Manual page 269

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Speed control under Real sensorless vector control, vector control, PM sensorless vector control
● Functions of terminals 1 and 4 by control (⎯ : no function)
Pr. 858 setting
value
0
(Initial value)
1
4
9999
Tab. 5-29:
When Pr. 868 ≠ "0", the other functions of terminal 1 (auxiliary input, override function, PID control)
do not operate.
When Pr. 858 ≠ "0", PID control and speed commands using terminal 4 do not operate even when
the AU signal is ON.
When both Pr. 858 and Pr. 868 are "1" (magnetic flux command) or "4" (torque limit), the function
of terminal 1 has higher priority, and terminal 4 does not function.
Valid when vector control compatible options are installed and vector control is selected.
FR-A800
Terminal 4 function
Speed command (AU signal-ON)
Magnetic flux command
Magnetic flux command
Torque limit (Pr. 810 =1)
Power driving torque limit (Pr. 810 = 1)
Torque limit (Pr. 810 = 1)
Torque limit (Pr. 810 = 1)
Terminal 1, 4 function according to control
Pr. 868 setting
Terminal 1 function
0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command
2
3
4
Torque limit (Pr. 810 = 1)
5
6
Torque bias (Pr. 840 = 1 to 3)
9999
0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command
2
3
4
Torque limit (Pr. 810 = 1)
5
6
Torque bias (Pr. 840 = 1 t o 3)
9999
0
Speed setting auxiliary
(Initial value)
1
Magnetic flux command
Regenerative driving torque limit
2
(Pr. 810 = 1)
3
4
Torque limit (Pr. 810 = 1)
5
6
Torque bias (Pr. 840 = 1 to 3)
9999
5 - 89