Installation and wiring
Reinstallation of the front covers
(FR-A820-01540(30K) or lower, FR-A840-00770(30K) or lower)
Insert the upper hooks of the front cover (upper side) into the sockets of the inverter.
Securely install the front cover (upper side) to the inverter by fixing the hooks on the sides of the
cover into place.
Tighten the mounting screw(s) at the lower part of the front cover (upper side).
(FR-A820-00340(5.5K) to FR-A820-01540(30K) and FR-A840-00170(5.5K) to FR-A840-00770(30K)
have two mounting screws.)
Install the front cover (lower side) by inserting the upper hook into the socket of the front cover
(upper side).
Tighten the mounting screws at the lower part of the front cover (lower side) .
Fig. 2-7:
NOTE
When installing the front cover (upper side), fit the connector of the operation panel securely
along the guides of the PU connector.
FR-A800
Removal and reinstallation of the operation panel or the front covers
Reinstallation of the front covers
Fasten
Fasten
I002348E