Mitsubishi Electric FR-A820-00046 Instruction Manual page 721

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
● The second PID function parameters and signals function in the same way as the following
parameters and signals of the first PID function. Refer to the first PID function when setting the
second PID functions.
Classification
Parameter
Tab. 5-228: Parameters for setting multiple PID functions
Classification
Input signal
Output signal
Tab. 5-229: I/O signals for setting multiple PID functions
FR-A800
First PID function parameters
Pr.
Name
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
553
PID deviation limit
554
PID signal operation selection
Output interruption detection
575
time
Output interruption detection
576
level
577
Output interruption cancel level
PID set point/deviation input
609
selection
PID measured value input
610
selection
First PID function parameters
Signal
Name
X14
PID control valid terminal
X64
During retry
X72
PID P control switchover
FUP
PID upper limit
FDN
PID lower limit
PID forward/reverse rotation
RL
output
PID
During PID control activated
SLEEP
PID output interruption
Y48
PID deviation limit
(A) Application parameters
Second PID function parameters
Pr.
Name
Second PID control automatic
754
switchover frequency
753
Second PID action selection
756
Second PID proportional band
757
Second PID integral time
1143
Second PID upper limit
1144
Second PID lower limit
755
Second PID action set point
758
Second PID differential time
1145
Second PID deviation limit
1146
Second PID signal operation selection
Second output interruption detection
1147
time
Second output interruption detection
1148
level
1149
Second output interruption cancel level
Second PID set point/deviation input
1140
selection
Second PID measured value input
1141
selection
Second PID function parameters
Signal
Name
X80
Second PID control valid terminal
Second PID forward/reverse action
X79
switchover
X73
Second PID P control switchover
FUP2
Second PID upper limit
FDN2
Second PID lower limit
Second PID forward/reverse rotation
RL2
output
PID2
Second During PID control activated
SLEEP2
During second PID output shutoff
Y205
Second PID deviation limit
5 - 541

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents