Mitsubishi Electric FR-A820-00046 Instruction Manual page 977

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Specifications
Dedicated motor (SF-V5RU(H)) outline dimension drawings
(standard horizontal type with brake)
Frame Number 90L
SF-V5RU(H) 1KB
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
L
A
KA
Exhaust
Suction
1
2
Mark for
Direction
earthing
of cooling
F
F
(grounding)
fan wind
N
Sliding distance
W
X
S
Frame leg viewed
Section AA
from above
indicates an inserting position
of a bolt with hex head holes
for manual opening.
Frame Number 160M, 160L, 180M, 180L
SF-V5RU(H) 11KB, 15KB, 18KB, 22KB
Connector
Terminal box for cooling fan
(for encoder)
MS3102A20-29P
L
A
KA
Suction
Exhaust
1, 2
Direction
Mark for earthing
of cooling
(grounding)
fan wind
F
Earth (ground)
N
terminal (M8)
Sliding distance
W
S
Section AA
indicates an inserting position
of a bolt with hex head holes
for manual opening.
Fig. 8-11:
Dedicated motor (SF-V5RU(H)) outline dimension drawings (standard horizontal type with brake)
NOTE
Make sure to earth the earth terminal of the frame installation foot as well as the earth terminal in
the terminal box.
FR-A800
R
KL
B
50
D
40
Main
terminal
box
A
A
XB
2
E
E
M
Earth (ground) terminal (M5)
Main terminal box
For brake (B1, B2)
For motor (U, V, W)
B1
B2
U
R
KL
110
B
D
Main
90
terminal
1
box
A
A
J
F
XB
E
E
M
X
Frame leg viewed
from above
Main terminal box
U
V
B1
B2
G1
For brake (B1, B2)
Frame Number 100L, 112M, 132S, 132M
SF-V5RU(H) 2KB, 3KB, 5KB, 7KB
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
A
Suction
1
1
2
Direction
Mark for
of cooling
earthing
fan wind
(grounding)
Earth (ground)
terminal (M5)
Terminal box for cooling fan
For thermal protector (G1, G2)
For cooling fan (A, B)
V
W
G1 G2
A
B
C
Earthing (grounding)
Earthing (grounding)
terminal (M4)
terminal (M4)
SF-V5RU(H) 30KB, 37KB, 45KB, 55KB
Connector (for encoder)
Terminal box for cooling fan
MS3102A20-29P
A
φ22
Suction
2
1, 2
Mark for earthing
Direction
(grounding)
of cooling
fan wind
Earth (ground)
terminal (M12)
For motor
Terminal box for cooling fan
(U, V, W)
For cooling fan (A, B, C)
Earthing
(ground-
ing) termi-
A
B
C
nal (M8)
W
Earthing (grounding)
terminal (M4)
G2
For thermal protector (G1, G2)
Outline dimension drawings
L
KL
R
KA
B
Q
QK
Exhaust
Main
terminal
box
A
A
J
F
F
XB
N
W
Frame leg viewed
from above
S
Section AA
indicates an inserting position
of a bolt with hex head holes
for manual opening.
I002481E, I002482E, I002483E
Frame Number 200L, 225S
L
R
B
140
Main ter-
KA
110
minal box
Exhaust
1
A
A
J
XB
F
F
N
W
S
from above
Section AA
indicates an inserting position
of a bolt with hex head holes
for manual opening.
I002484E, I002486E, I002485E
D
1
2
E
E
M
ML
Sliding distance
X
D
2
E
E
M
Sliding distance
X
Frame leg
viewed
8 - 23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents