Appendix
A.3
Parameters (function codes) and instruction codes under
different control methods
Instruction codes are used to read and write parameters in accordance with the Mitsubishi inverter
protocol of RS-485 communication.
(For RS-485 communication, refer to page 5-610.)
Function availability under each control method is shown as below:
: Available
×: Not available
Δ: Available only during position control set by parameter
If function availability differs between using induction motors with an encoder and using PM
motors with a resolver, the function availability using PM motors with a resolver is described in
parentheses. Also, a PM motor with a resolver is not available under the torque control.
For "parameter copy", "parameter clear", and "all parameter clear", "" indicates the function is
available, and "×" indicates the function is not available.
These parameters are not cleared by the parameter clear (all parameter clear) command, which
are sent through RS-485 communication. (For RS-485 communication, refer to page 5-610.)
When a communication option is installed, parameter clear (lock release) during password lock
(Pr. 297 ≠ "9999") can be performed only from the communication option.
Available when the IPM motor MM-CF series is used and the low-speed range high-torque char-
acteristic is enabled (Pr. 788 = "9999 (initial value)").
Reading and writing via the PU connector are available.
Symbols in the table indicate parameters that operate when the options are connected.
FR-A8AP,
FR-A8NCE,
Pr.
Name
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
Tab. A-3:
Parameter list with instruction codes (1)
FR-A800
Parameters (function codes) and instruction codes under different control methods
FR-A8TP,
FR-A8APR,
FR-A8ND,
FR-A8AZ,
Instruction code
00
80
0
01
81
0
02
82
0
03
83
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
FR-A8AR,
FR-A8AX,
FR-A8NP
Control method
Vector
Vector
Vector
Sensorless
Sensorless
Sensorless
x
x
x
x
x
x
x
x
x
x
x
Δ
Δ
Δ
Δ
Δ
x
FR-A8AY,
FR-A8NC,
Parameter
PM
PM
PM
x
x
x
x
x
x
x
Δ
Δ
Δ
Δ
Δ
x
A - 5