(E) Environment setting parameters
Initial values differ depending on the rating as follows.
Pr.
0 [%]
7 [s]
8 [s]
12
[%]
Tab. 5-72:Initial values of Pr. 0, Pr. 7, Pr. 8 and Pr. 12 depending on Pr. 570 setting
The rated current and motor capacity differ depending on the inverter capacity. Refer to the
inverter rated specifications (page 8-1).
The initial value for FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, is set to
85% of the rated inverter current.
● Setting Pr. 292 "Automatic acceleration/deceleration" = "5 or 6 (lift mode)" will change the stall
prevention operation level as shown below.
Pr.
292
Tab. 5-73:
NOTES
When Pr. 570 = "0" (SLD rating), carrier frequency automatic reduction is enabled regardless of the
setting in Pr. 260 "PWM frequency automatic switchover".
To use the FR-A820-03160(55K) and FR-A840-01800(55K) in the LD and SLD ratings, a DC reactor,
which is available as an option, corresponding to the applied motor is required.
Setting the LD or SLD rating to the FR-A820-03160(55K) and FR-A840-01800(55K) changes their
parameter setting increments and setting ranges in the same way as for the FR-A820-03800(75K)
and FR-A840-02160(75K) or higher. For example, the setting increment and the setting range of
Pr. 9 will change from "0.01 A" to "0.1 A" and from "0 to 500 A" to "0 to 3600 A". For the setting of
each parameter, refer to the parameter list (on page 5-2).
Parameters referred to
Pr. 260
5 - 202
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
(0.4K) (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) (30K) (37K) (45K) (55K) (75K) (90K)
00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 00770 00930 01160 01800 02160 02600
(0.4K) (0.75K) (1.5K) (2.2K) (3.7K)s (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) (30K) (37K) s(45K) (55K) (75K) (90K)
0, 1
6
4
4
4
2
6
6
4
4
3
6
6
6
4
0, 1
5
5
5
5
2
5
5
5
5
3
5
5
5
5
0, 1
10
10
10
10
2
5
5
5
5
3
5
5
5
5
0, 1
4
4
4
4
2
4
4
4
4
3
4
4
4
4
Setting
0
5
110%
6
115%
Influence of Pr. 292 on the stall prevention operation level
PWM frequency automatic switchover
200 V class FR-A820-
400 V class FR-A840-
3
3
2
2
2
4
3
3
2
2
4
4
3
3
2
5
5
15
15
15
5
5
5
15
15
5
5
5
5
15
10
10
30
30
30
5
5
5
15
15
5
5
5
5
15
4
4
2
2
2
4
4
4
2
2
4
4
4
4
2
Pr. 570 setting
1
2 (Initial value)
120%
140%
2
2
2
1.5
1.5
2
2
2
2
2
2
2
2
2
2
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
30
30
30
30
30
15
15
15
15
15
15
15
15
15
15
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
150%
200%
180%
230%
=>
page 5-219
Parameters
or
higher
1
1
1
2
1
1
2
2
1
15
15
15
15
15
15
15
15
15
30
30
30
15
15
15
15
15
15
1
1
1
2
1
1
2
2
1
Refer to
5-260

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents