T) Multi-Function Input Terminal Parameters - Mitsubishi Electric FR-A820-00046 Instruction Manual

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
5.12

(T) Multi-Function Input Terminal Parameters

Purpose
To inverse the rotation direction with
the voltage/current analog input
selection (terminals 1, 2, and 4)
To assign functions to analog input
terminals
To adjust the main speed by the
analog auxiliary input
To eliminate noise on analog inputs
To adjust analog input frequency/
voltage (current) (calibration)
To adjust analog input torque/
voltage (current) (calibration)
To continue operating at analog
current input loss
To assign functions to input terminals
To change the input specification
(NO/NC contact) of input signals
To enable the second (third) function
only during the constant speed
To assign start and forward/reverse
commands to different signals
5.12.1
Analog input selection
The functions to switch the analog input terminal specifications, override function, forward/reverse
rotation by the input signal polarity are selectable.
Pr.
73
T000
267
T001
FR-A800
Parameter to set
Analog input selection
Terminal 1 and terminal 4
function assignment
Analog auxiliary input and
compensation (addition
compensation and override
functions)
Analog input filter
Frequency setting voltage
(current) bias and gain
Torque setting voltage
(current) bias and gain
4-mA input check
Input terminal function
selection
Output stop signal (MRS)
input selection
Inverter run enable signal
(X10) input selection
Power failure stop external
signal (X48) input selection
RT signal application period
selection
Start signal (STF/STR)
operation selection
Name
Initial value
Analog input selection
Terminal 4 input
selection
(T) Multi-Function Input Terminal Parameters
P.T000, P.T001
P.T010, P.T040
P.T021, P.T031,
P.T050, P.T051
P.T002 to P.T007
P.T100 to P.T103,
P.T200 to P.T203,
P.T400 to P.T403,
P.M043
P.T110 to P.T113,
P.T410 to P.T413,
P.M043
P.T052 to P.T054
P.T700 to P.T711,
P.T740
P.T720
P.T721
P.T722
P.T730
P.G106
Setting
range
Switch 1 - OFF
0 to 5,
10 to 15
(initial status)
1
6, 7, 16, 17
Switch 1 - ON
Switch 2 - ON
0
(initial status)
0
1
Switch 2 - OFF
2
Refer to
page
Pr. 73, Pr. 267
5-389
Pr. 858, Pr. 868
5-394
Pr. 73, Pr. 242,
Pr. 243, Pr. 252,
5-395
Pr. 253
Pr. 74, Pr. 822,
Pr. 826, Pr. 832,
5-399
Pr. 836, Pr. 849
Pr. 125, Pr. 126,
Pr. 241, C2 to C7
(Pr. 902 to Pr. 905),
5-401
C12 to C15
(Pr. 917 to Pr. 918)
Pr. 241, C16 to C19
(Pr. 919 to Pr. 920),
5-409
C38 to C41
(Pr. 932 to Pr. 933)
Pr. 573, Pr. 777,
5-399
Pr. 778
Pr. 178 to Pr. 189,
5-422
Pr. 699
Pr. 17
5-426
Pr. 599
5-679
Pr. 606
5-580
Pr. 155
5-428
Pr. 250
5-430
Description
The terminal 2 input specification
(0 to 5 V, 0 to 10 V, 0 to 20 mA) and
terminal 1 input specification (0 to
±5 V, 0 to ±10 V) are selectable.
Also the override and reversible
operation settings are selectable.
Terminal 4 input, 4 to 20 mA
Terminal 4 input, 0 to 5 V
Terminal 4 input, 0 to 10 V
5 - 389

Hide quick links:

Advertisement

Table of Contents
loading