Parameter List
Pr.
Pr.
Name
group
Increased magnetic excitation
G132
662
current level
G200
800
Control method selection
G203
245
Rated slip
G204
246
Slip compensation time constant
Constant-power range slip
G205
247
compensation selection
Constant output range speed
G206
1116
control P gain compensation
Constant output range torque
G210
803
characteristic selection
G211
820
Speed control P gain 1
G212
821
Speed control integral time 1
Torque control P gain 1 (current loop
G213
824
proportional gain)
Torque control integral time 1
G214
825
(current loop integral time)
G215
Speed detection filter 1
823
G216
827
Torque detection filter 1
G217
854
Excitation ratio
Speed control integral term clear
G218
1115
time
Speed feed forward control/model
G220
877
adaptive speed control selection
G221
878
Speed feed forward filter
G222
879
Speed feed forward torque limit
G223
881
Speed feed forward gain
G224
828
Model speed control gain
G230
840
Torque bias selection
G231
841
Torque bias 1
G232
842
Torque bias 2
G233
843
Torque bias 3
G234
844
Torque bias filter
G235
845
Torque bias operation time
G236
846
Torque bias balance compensation
G237
847
Fall-time torque bias terminal 1 bias
G238
848
Fall-time torque bias terminal 1 gain
G240
Speed feedback range
367
G241
Feedback gain
368
Tab. 5-16:
Control Parameter (2)
Setting can be made only when a vector control compatible option is mounted.
Setting can be made only when the FR-A8AP is mounted.
The setting is available only when the FR-A8AP or the FR-A8APR is mounted.
The setting is available only when the FR-A8TP is mounted.
The setting is available only when the FR-A8AP or the FR-A8TP is mounted.
The parameter number in parentheses is the one for use with the LCD operation panel (FR-LU08) and the parameter
unit (FR-PU07).
Setting can be made only for the standard model.
Setting can be made only for the standard model and the IP55 compatible model.
The setting is available only with the 400 V class.
5 - 48
Refer to
Pr.
Pr.
page
group
5-689
G250
788
5-56
G260
1121
5-691
G261
1117
5-691
5-691
G262
1119
5-97
G300
451
5-84,
G311
830
5-132
G312
831
5-97
G313
834
5-97
G314
835
5-144
G315
833
G316
837
5-144
G350
747
5-186
5-186
G361
1118
5-187
G400
286
5-97
G401
287
5-109
G402
288
5-181
G403
994
5-109
G404
995
5-109
G410
653
5-109
G411
654
5-109
G420
679
5-113
G421
680
5-113
G422
681
5-113
G423
682
5-113
G424
683
5-113
G601
1003
5-113
5-113
G602
1004
5-113
G603
1005
5-113
G932
89
5-692
G942
569
5-692
Tab. 5-16:
Name
Low speed range torque
characteristic selection
Per-unit speed control reference
frequency
Speed control P gain 1 (per-unit
system)
Model speed control gain (per-unit
system)
Second motor control method
selection
Speed control P gain 2
Speed control integral time 2
Torque control P gain 2
Torque control integral time 2
Speed detection filter 2
Torque detection filter 2
Second motor low-speed range
torque characteristic selection
Speed control P gain 2 (per-unit
system)
Droop gain
Droop filter time constant
Droop function activation selection
Droop break point gain
Droop break point torque
Speed smoothing control
Speed smoothing cutoff frequency
Second droop gain
Second droop filter time constant
Second droop function activation
selection
Second droop break point gain
Second droop break point torque
Notch filter frequency
Notch filter depth
Notch filter width
Speed control gain (Advanced
magnetic flux vector)
Second motor speed control gain
Control Parameter (3)
Parameters
Refer to
page
5-75
5-97
5-97
5-109
5-56,
5-147
5-97
5-97
5-144
5-144
5-186
5-186
5-75
5-97
5-695
5-695
5-695
5-695
5-695
5-699
5-699
5-695
5-695
5-695
5-695
5-695
5-121
5-121
5-121
5-67
5-67