Parameters
NOTES
When parameter settings are copied to USB memory without specifying a parameter setting file
number in USB memory, numbers are automatically assigned.
Up to 99 files can be saved on USB memory. When the USB memory device already has 99 files,
attempting copying of another file to the USB memory device causes the file quantity error (rE7).
Refer to the FR Configurator2 instruction manual for details on importing files to FR Configurator2.
During password lock, parameter copy and parameter verification cannot be performed (refer to
page 5-207).
Procedure for copying parameters to USB memory
Insert the USB memory into the copy source inverter.
USB memory mode
Press
Displaying the file selection screen
Press
memory, display the file selection screen, turn
Copying to USB memory
Turn
(It takes about 15 seconds to copy all the settings. During copying, "
"
Tab. 5-323: Copying parameters to USB memory
FR-A800
to change to the USB memory mode.
three times to display
to change to "
". Press
" and "file number when the parameter file was copied to USB memory" flicker after copying ends.
Copying and verifying parameters using USB memory
Operation
(file selection screen) and press
to select the file number, and press
to copy the parameter settings at the copy source to USB memory.
" flickers.)
. (To overwrite files on USB
.)
5 - 705