Mitsubishi Electric FR-A820-00046 Instruction Manual page 616

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

(C) Motor constant parameters
Pr. 71
5
15
6
16
Tab. 5-171: Setting of parameter Pr. 71 and Pr. 450 (2)
The setting is available for FR-A820-00630(11K) or lower.
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
The same operation is performed for both settings.
NOTES
Regardless of the Pr. 71 (Pr. 450) setting, offline auto tuning can be performed according to Pr. 96
(Pr. 463) "Auto tuning setting/status". (Refer to page 5-67 for offline auto tuning.)
5 - 436
Pr.
Motor
450
Standard motor
Constant-torque motor
Standard motor
Constant-torque motor
9999
(initial
No second applied motor
value)
Constant value range when
performing offline auto tuning
(increment)
Pr. 82 (Pr. 455) and Pr. 859
(Pr. 860)
0 to 500 A, 9999 (0.01 A)
0 to 3600 A, 9999 (0.1 A)
Pr. 90 (Pr. 458) and
Pr. 91(Pr. 459)
0 to 50 Ω, 9999 (0.001 Ω)
0 to 400 mΩ, 9999
(0.01 mΩ)
Pr. 92 (Pr. 460) and Pr. 93
(Pr. 461)
0 to 50 Ω, 9999 (0.001 Ω)
0 to 3600 mΩ, 9999
(0.1 mΩ)
Pr. 94 (Pr. 462)
0 to 500 Ω, 9999 (0.01 Ω)
0 to 100 Ω, 9999 (0.01 Ω)
Parameters
Operational characteristic
of the electronic thermal O/L
relay
Stand-
Constant
PM
-torque
ard

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents