Connection of motor with encoder (vector control)
● When using an encoder cable (FR-JCBL, FR-V5CBL, etc.) dedicated to the conventional motor, cut
the crimping terminal of the encoder cable and strip its sheath to make its cable wires loose.
Also, treat the shielding wires of the shielded twisted pair cable to ensure that they will not contact
conductive areas.
Wire the stripped cable after twisting it to prevent it from becoming loose. In addition, do not
solder it.
Fig. 2-47:
NOTES
Information on blade terminals
Commercially available products (as of January 2015)
● Phoenix Contact Co., Ltd.
Terminal screw
● NICHIFU Co.,Ltd.
Terminal screw
When using a blade terminal (without insulation sleeve), take caution that the twisted wires do
not come out.
2 - 66
Cable stripping size
5 mm
Preparation of the cable
Cable gauge
2
size
(mm
)
M2
0.3, 0.5
Cable gauge
2
size
(mm
)
M2
0.3 to 0.75
Blade terminal model
With insulation sleeve
Without insulation sleeve
AI 0,5-6WH
Blade terminal product
Insulation product number
number
BT 0.75-7
Installation and wiring
Crimping tool
name
A 0,5-6
CRIMPFOX 6
Crimping tool
product number
VC 0.75
NH 69
I002397E