(A) Application parameters
Setting the upper and lower limits of the PID manipulated amount (Pr. 1134, Pr. 1135)
● Set the upper and lower limits of the PID manipulated amount.
● The upper limit of the manipulated amount is the frequency obtained by adding the value
resulting from frequency conversion of Pr. 1134 to the main speed.
The lower limit of the manipulated amount is the frequency obtained by subtracting the value
resulting from frequency conversion of Pr. 1135 from the main speed.
Fig. 5-278:
5 - 558
Upper and lower limits of the PID manipulated amount
Upper limit of PID manipulated amount
Main speed
Lower limit of PID manipulated
amount
Output frequency considering upper/lower limit
of PID manipulated amount
Time