Mitsubishi Electric FR-A820-00046 Instruction Manual page 965

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Specifications
Pulse train
output
(FM type)
Current
For meter
output
(CA type)
Voltage
output
Operating
Operation
status
panel
(FR-DU08)
Fault record
Protective
function
Protective/
warning
function
Warning
function
Surrounding air
temperature
Surrounding air humidity
Storage temperature
Atmosphere
Altitude/vibration
Tab. 8-10:
Common specifications (2)
Available only when a vector control compatible option is mounted.
Temperature applicable for a short time, e.g. in transit.
For the installation at an altitude above 1,000 m up to 2,500 m, derate the rated current 3% per
500 m.
This protective function is not available in the initial status.
For PM sensorless vector control, refer to page A-4.
In the initial setting for the FR-A820-00340(5.5K) or higher and the FR-A840-00170(5.5.K) or higher,
the starting torque is limited to 150% by the torque in level.
Available only for the IP55 compatible model.
Available only for the standard model and the IP55 compatible model.
Available only for the standard model.
FR-A800
Max. 2.4 kHz: one terminal (output frequency)
The monitored item can be changed using Pr. 54 "FM/CA terminal function selection".
Max. 20 mA DC: one terminal (output current)
The monitored item can be changed using Pr. 54 "FM/CA terminal function selection".
Max. 10 V DC: one terminal (output voltage)
The monitored item can be changed using Pr. 158 "AM terminal function selection".
Output frequency, Output current, Output voltage, Frequency setting value
The monitored item can be changed using Pr. 52 "Operation panel main monitor selection".
Fault record is displayed when a fault occurs. Past 8 fault records and the conditions immediately before the
fault (output voltage/current/frequency/cumulative energization time/year/month/date/time) are stored.
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during
deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during
constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip, Motor
overload trip, Heatsink overheat, Instantaneous power failure , Undervoltage , Input phase loss
prevention stop, Loss of synchronism detection , Brake transistor alarm detection, Output side earth (ground)
fault overcurrent, Output short circuit, Output phase loss, External thermal relay operation , PTC thermistor
operation , Option fault, Communication option fault, Parameter storage device fault, PU disconnection,
Retry count excess , Parameter storage device fault, CPU fault, Operation power supply short circuit/ RS-485
terminal power supply short circuit, 24 V DC power fault, Abnormal output current detection, , Inrush current
limit circuit fault , Communication fault (inverter), Analog input fault, USB communication fault, Safety circuit
fault, Overspeed occurrence , Speed deviation excess detection
position fault
, Brake sequence fault , Encoder phase fault
signal fault , Option fault, Internal circuit fault , Abnormal internal temperature , Magnetic pole position
unknown
Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm
Electronic thermal relay function pre-alarm, PU stop, Speed limit indication , Parameter copy, Safety stop,
Maintenance signal output , USB host error, Home position return setting error , Home position return
uncompleted , Home position return parameter setting error , Operation panel lock , Password locked ,
Parameter write error, Copy operation error, 24 V external power supply operation, Internal fan alarm
-10 °C to +50 °C (non-freezing) (LD, ND, HD ratings)
-10 °C to +40 °C (non-freezing) (SLD rating, IP55 compatible models)
With circuit board coating (conforming to IEC60721-3-3 3C2/3S2, IP55 compatible models:
95% RH or less (non-condensing),
Without circuit board coating:
90% RH or less (non-condensing)
-20 °C to +65 °C
Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Maximum 1000 m above sea level ,
2
2
5.9 m/s
or less (2.9 m/s
for the FR-A840-04320(160K) or higher) at 10 to 55 Hz (directions of X, Y, Z axes)
Common specifications
, Signal loss detection
, Excessive
, 4 mA input fault , Pre-charge fault , PID
, Stall
,
8 - 11

Hide quick links:

Advertisement

Table of Contents
loading