Mitsubishi Electric FR-A820-00046 Instruction Manual page 701

Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Parameters
Machine end orientation connection diagram (Vector control)
To perform machine end orientation control, the following settings are required.
– Install a plug-in option (FR-A8AP or FR-A8APR) and a control terminal option (FR-A8TP) to the
inverter, a motor end encoder to the control terminal option, and a machine end encoder to the
plug-in option.
– Set Pr. 862 "Encoder option selection" = "1".
– Set Pr. 393 "Orientation selection" = "10 to 12" (refer to page 5-516).
– Set the gear ratio by setting Pr. 394 "Number of machine side gear teeth" and Pr. 395 "Number of
motor side gear teeth" (refer to page 5-523).
Machine end orientation connection example
MCCB
MC
Three-
phase
AC power
supply
Forward rotation start
Reverse rotation start
Orientation command
Contact input common
Fig. 5-253:
Machine end orientation connection example
The power supply of the fan for a 7.5 kW or lower dedicated motor is single phase. (200 V/50 Hz,
200 to 230 V/60 Hz)
The pin number differs according to the encoder used.
Use Pr. 178 to Pr. 182, Pr. 185, or Pr. 189 (input terminal function selection) to assign the function
to a terminal. (Refer to page 5-422.)
Use Pr. 190 to Pr. 192, or Pr. 195 (output terminal function selection) to assign the function to a
terminal. (Refer to page 5-361.)
Connect the encoder so that there is no looseness between the motor and motor shaft. Speed
ratio must be 1:1.
FR-A800
Inverter
R/L1
U
S/L2
V
W
T/L3
Earth
(Ground)
FR-A8TP
PA3
STF
PAR3
STR
X22
PB3
SD
PBR3
ORA
Differential
PZ3
ORM
PZR3
Complementary
SE
PG
SD
SD
Terminating
resistor ON
PG
SD
(+)
OFF
FR-A8AX
FR-A8AP
X15
PA1
X14
PA2
Differential
X1
PB1
X0
PB2
Complementary
DY
PZ1
Terminating
PZ2
resistor ON
PG
SD
OFF
PG
SD
(+)
SF-JR motor with encoder
U
M
V
~
W
E
C
R
A
N
Encoder
B
P
H
K
5 V DC power
(-)
supply
A
A
B
B
Encoder
Z
Z
+
-
Power supply
(-)
(A) Application parameters
For complementary type (SF-V5RU)
MCCB
MC
OCR
SF-V5RU
Three-phase
AC power
supply
U
U
Inverter
V
V
W
W
E
Thermal
FR-A8TP
PC
relay
Earth
External
protector
(Ground)
OH
thermal
G1
relay input
G2
SD
PA3
A
PAR3
B
PB3
C
Differential
PBR3
D
F
PZ3
Complementary
PZR3
G
Terminating
PG
S
resistor ON
SD
R
PG24
OFF
FR-A8AP
PA1
A
PB1
B
Differential
PZ1
Z
Complementary
Terminating
PG
+
resistor ON
SD
-
PG
SD
OFF
Power supply
(-)
(+)
FAN
M
~
Encoder
Encoder
I002872E
5 - 521

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents