Installation and wiring
2.2
Removal and reinstallation of the operation panel or the
front covers
Removal and reinstallation of the operation panel
Loosen the two screws on the operation panel. (These screws cannot be removed.)
Press the upper edge of the operation panel while pulling out the operation panel.
Fig. 2-4:
To reinstall the operation panel, align its connector on the back with the PU connector of the inverter,
and insert the operation panel. After confirming that the operation panel is fit securely, tighten the
screws. (Tightening torque: 0.40 to 0.45 Nm)
FR-A800

Removal and reinstallation of the operation panel or the front covers

Removal and reinstallation of the operation panel
I002344E, I002345E