Example For Configuring Link Aggregation In Static Lacp Mode - Huawei Quidway S9300 Configuration Manual

Terabit routing switch
Table of Contents

Advertisement

2 Link Aggregation Configuration
[S9300] interface eth-trunk 120
[S9300-Eth-Trunk120] port link-type trunk
[S9300-Eth-Trunk120] port trunk allow-pass vlan 100 to 200
[S9300-Eth-Trunk120] quit
Step 4 Verify the configuration.
Run the display trunkmembership command in any view to check whether Eth-Trunk 120 is
created and whether member interfaces are added.
[S9300] display trunkmembership eth-trunk 120
Trunk ID: 120
used status: VALID
TYPE: ethernet
Working Mode : Normal
Working State: Normal
Number Of Ports in Trunk = 2
Number Of UP Ports in Trunk = 2
operate status: up
Interface GigabitEthernet2/0/0, valid, selected, operate up, weight=1,
standby interface NULL
Interface GigabitEthernet3/0/0, valid, selected, operate up, weight=1,
standby interface NULL
# Display the configuration of Eth-Trunk 120.
[S9300] display eth-trunk 120
Eth-Trunk120's state information is:
WorkingMode: NORMAL
Least Active-linknumber: 1
Operate status: up
--------------------------------------------------------------------------------
PortName
GigabitEthernet2/0/0
GigabitEthernet3/0/0
The preceding information indicates that Eth-Trunk 120 consists of member interfaces GE 2/0/0
and GE 3/0/0. The member interfaces are both in Up state.
----End
Configuration Files
Configuration file of the S9300
#
sysname S9300
#
interface Eth-Trunk120
port link-type trunk
port trunk allow-pass vlan 100 to 200
#
interface GigabitEthernet2/0/0
eth-trunk 120
#
interface GigabitEthernet3/0/0
eth-trunk 120
#
return
2.7.2 Example for Configuring Link Aggregation in Static LACP
Mode
2-22
Hash arithmetic: According to SA-XOR-DA
Max Bandwidth-affected-linknumber: 8
Number Of Up Port In Trunk: 2
Status
Up
1
Up
1
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Quidway S9300 Terabit Routing Switch
Weight
Configuration Guide - Ethernet
Issue 03 (2009-08-20)