High Capacity Delta Ac Pdu Leds; Table 22: Three-Phase Wye Ac Pdu Leds - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Table 22: Three-Phase Wye AC PDU LEDs

LED
—One per power
PDU OK
supply
220-240 V/346-415 V
30 A
50-60 Hz
CB ON

High Capacity Delta AC PDU LEDs

Copyright © 2017, Juniper Networks, Inc.
Color
Green
Red
Green
Green
Figure 42 on page 64
shows the High Capacity Delta AC PDU LEDs.
Chapter 4: Power System Components and Descriptions
State
Description
On steadily
PDU is functioning normally.
On steadily
PDU has failed.
Off
This LED can be off for one of the following
reasons:
The PDU is not receiving any input voltage.
The circuit breaker might be off.
The PDU is starting up.
On steadily
PDU is receiving AC voltage.
Off
AC input voltage is not present, or is under
–100 VAC.
On steadily
Circuit breaker is powered on.
Off
This LED can be off for one of the following
reasons:
Circuit breaker is not powered on. The circuit
breaker might have been turned off, or the
host subsystem detected a failure and turned
off the circuit breaker.
The PDU is not receiving any input voltage.
The circuit breaker is on but the input voltage
is under –100 VAC.
63

Advertisement

Table of Contents
loading

Table of Contents