Table 81: Troubleshooting Chassis Alarm Messages For The Ccgs; Table 82: Troubleshooting Ccg Leds; Table 83: Troubleshooting Ccg Port Leds - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

PTX5000 Packet Transport Router Hardware Guide

Table 81: Troubleshooting Chassis Alarm Messages for the CCGs

Alarm Type
LCD Message
Red
CCG CCG-number
Failure
No CG Online
CCG CCG-number Ext-A
LOS
CCG CCG-number Ext-B
LOS
CCG CCG-number EXT
SYNC UNSUPP
Yellow
CCG CCG-number Not
Online

Table 82: Troubleshooting CCG LEDs

Label
Color
Yellow
FAIL
OK

Table 83: Troubleshooting CCG Port LEDs

Label
FAULT
LINK
NOTE:
The
LINK
LEDs are supported
only for the BITS ports. This LED is
not supported for the GPS ports.
Related
Documentation
508
CLI Message
CCG CCG-number
Failure
No CG Online
CCG CCG-number
External-A LOS
CCG CCG-number
External-B LOS
CCG CCG-number
EXT SYNC UNSUPP
CCG CCG-number Not
Online
State
Description
On steadily
The CCG has detected a failure.
Off
The CCG is not online or is not
powered on.
Color
Yellow
Yellow
PTX5000 Centralized Clock Generator Description on page 23
PTX5000 Centralized Clock Generator LEDs on page 24
Maintaining the PTX5000 Centralized Clock Generators on page 482
Alarm Condition
A CCG has failed.
No CCGs are installed, or the
CCGs installed are not online
Loss of signal has occurred on
the Bits-A port configured to be
the primary or secondary
clocking source, .
Loss of signal has occurred on
the Bits-B port configured to be
the primary or secondary
clocking source.
External synchronization is not
supported.
A CCG is offline.
Recovery
Replace the CCG.
Bring the CCG online.
State
Description
On steadily
The CCG has detected a failure.
On steadily
BITS loss of signal
Off
No loss of signal
Copyright © 2017, Juniper Networks, Inc.