Juniper PTX3000 Quick Start Manual

Packet transport router
Hide thumbs Also See for PTX3000:
Table of Contents

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Juniper PTX3000

  • Page 1: Table Of Contents

    Step 4: Install the PTX3000 | 9 Step 5: Connect the PTX3000 Grounding Cable | 15 Step 6: Connect External Devices and PIC Cables to the PTX3000 | 17 Connect the PTX3000 to a Console or Auxiliary Device | 17...
  • Page 2 Step 7: Connect the PTX3000 to Power | 23 Connect AC Power to the PTX3000 AC Power Supply Modules | 24 Connect Nonredundant AC Power to the PTX3000 AC Power Supply Modules | 24 Connect Redundant AC Power to the PTX3000 AC Power Supply Modules | 24...
  • Page 3: Quick Start Description

    PTX3000 Packet Transport Router Hardware Guide https://www.juniper.net/documentation/. The PTX3000 is shipped in a wooden crate. A wooden pallet forms the base of the crate. The chassis is bolted to this pallet. The shipping crate also contains an accessory box and this Quick Start...
  • Page 4 For service personnel to remove and install hardware components, there must be adequate space at the front of the chassis. At least 24 in. (61.0 cm) is required in front of the PTX3000. NEBS GR-63 recommends that you allow at least 30 in. (72.6 cm) in front of the rack.
  • Page 5 Figure 1: Chassis Dimensions and Clearance Requirements...
  • Page 6: Tools Required To Unpack And Install The Ptx3000

    Phillips (+) screwdriver, number 2 1/2-in. or 13-mm open-end or socket wrench to remove bracket bolts from the shipping pallet Gather the tools and parts required to install the PTX3000 in a rack: Mechanical lift Screwdriver appropriate for your mounting screws (a number 1 Phillips (+) screwdriver is required for...
  • Page 7: Step 2: Unpack The Ptx3000

    1. Insert cage nuts in the holes specified for the mounting shelf (see Table 1 on page NOTE: A mounting shelf is not required to install the PTX3000. Table 1: Mounting-Hole Locations for Installing a PTX3000 Mounting Shelf Hole Distance Above U Division 0.02 in.
  • Page 8: Install The Mounting Shelf

    Table 2: Mounting-Hole Locations for Installing a Chassis Hole Distance Above U Division 4.9 in. (12.5 cm) 2.8 U 15.4 in. (39.1 cm) 8.8 U 29.9 in. (76.0 cm) 17.1 U Install the Mounting Shelf Optionally, you can install the mounting shelf before mounting the chassis in the rack. To install the mounting shelf (see Figure 3 on page 1.
  • Page 9: Step 4: Install The Ptx3000

    Use these handles only to help position the PTX3000. 2. Using the lift, position the PTX3000 in front of the rack. Lift the chassis slightly above the position you plan to install it, and position it as close as possible to the rack.
  • Page 10 5. Move the lift away from the rack. 6. If you are installing two to four routers in the rack, repeat this procedure for each router. See Figure 6 on page 13 Figure 7 on page 14 for examples of multiple routers installed in a single rack. Table 3: Mounting-Hole Locations for Installing a Chassis in a Rack Hole Distance Above U Division...
  • Page 11 Figure 4: Loading the PTX3000 onto the Lift...
  • Page 12 Figure 5: Installing the PTX3000 in a Rack...
  • Page 13 Figure 6: Installing Two Routers in a Rack (Front View) PTX3000 PTX3000 Upper chassis Lower chassis — —...
  • Page 14 Figure 7: Installing Four Routers in a Rack (Side View) Upper chassis 1 Lower chassis 1 — — Upper chassis 2 Lower chassis 2 — —...
  • Page 15: Step 5: Connect The Ptx3000 Grounding Cable

    See the instructions for your site. 3. Connect the grounding cable to a proper earth ground. 4. Verify that a licensed electrician has attached the cable lug provided with the PTX3000 to the grounding cable. 5. Ensure that grounding surfaces are clean and brought to a bright finish before you connect the grounding cable.
  • Page 16 Figure 8: Connecting the Grounding Cable...
  • Page 17: Step 6: Connect External Devices And Pic Cables To The Ptx3000

    18). To connect the cables to a management console or auxiliary device: 1. To connect the PTX3000 to external devices, you need an electrostatic discharge (ESD) grounding wrist strap (provided in the accessory box). 2. Attach an ESD grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis.
  • Page 18: Connect The Ptx3000 To A Network For Out-Of-Band Management

    To connect the management Ethernet ports on each Control Board or Routing and Control Board (RCB) to a network for management of the PTX3000, connect a UTP Category 5 Ethernet cable with an RJ-45 connector to the HOST/ETHERNET port on a Control Board, or the MGT port on an RCB.
  • Page 19 CAUTION: During the initial installation before the chassis is grounded, you must connect the wrist strap to an approved site ESD point. See the instructions for your site. 3. Plug one end of a UTP Category 5 Ethernet cable (Figure 10 on page 19 shows the connector) into the management Ethernet port on the Control Board or RCB in slot CB0 (see Figure 11 on page...
  • Page 20: Connect Pic Cables To The Ptx3000

    Connect PIC Cables to the PTX3000 The PTX3000 supports PICs and IPLCs that use various kinds of network cable, including multimode and single-mode fiber-optic cable. For information about the type of cable used by each PIC, see the PTX Series Interface Module Reference.
  • Page 21 5. Using a number 1 Phillips (+) screwdriver, loosen the two inner captive screws on the upper or lower cable management system. Move the cover of the upper cable management system up (Figure 14 on page 22). Move the cover of the lower cable management system down (Figure 15 on page 22).
  • Page 22 Figure 13: Connecting IPLC Cables with LC Connectors Figure 14: Upper Cable Management System Figure 15: Lower Cable Management System...
  • Page 23: Step 7: Connect The Ptx3000 To Power

    The IPLC cables are arranged similar to the PIC cables shown in Figure 16 on page Step 7: Connect the PTX3000 to Power IN THIS SECTION Connect AC Power to the PTX3000 AC Power Supply Modules | 24 Connect DC Power to the PTX3000 DC Power Supply Modules | 27...
  • Page 24: Connect Ac Power To The Ptx3000 Ac Power Supply Modules

    Connect Redundant AC Power to the PTX3000 AC Power Supply Modules | 24 Connect Nonredundant AC Power to the PTX3000 AC Power Supply Modules To connect nonredundant power, see Connecting Nonredundant AC Power to the PTX3000 AC Power Supply Modules in the PTX3000 Packet Transport Router Hardware Guide.
  • Page 25 Figure 17: Removing an AC PSM 6. Set the input switches for redundant power by setting both switches for input 1 and 2 to the on position (ON). Figure 18: Setting the Input Switches for Redundant Power Input 1 switch ON Input 2 switch ON —...
  • Page 26 Figure 19: Connecting the AC Power Cords to a PSM 8. Insert the power cord plug into an external AC power receptacle. 9. Reinstall the PSM into the chassis (see Figure 20 on page 26), and tighten the captive screw to secure Figure 20: Installing an AC PSM 10.
  • Page 27: Connect Dc Power To The Ptx3000 Dc Power Supply Modules

    Connect Redundant DC Power to the PTX3000 DC Power Supply Modules | 27 Connect Nonredundant DC Power to the PTX3000 DC Power Supply Modules To connect nonredundant power, see Connecting Nonredundant DC Power to the PTX3000 DC Power Supply Modules in the PTX3000 Packet Transport Router Hardware Guide.
  • Page 28 4. Switch the power switch on the power supply module (PSM) faceplate to the standby position ( 5. Loosen the captive screw on the PSM. 6. Grasp the PSM, and pull it out to remove it from the chassis (see Figure 21 on page 28).
  • Page 29 10. Connect the positive (+) DC source power cables to input 1 and input 2 RTN (return) input terminals (Figure 23 on page 30 Figure 24 on page 30). CAUTION: One input on each DC PSM must be powered by dedicated power feeds derived from feed A, and the other input on each PSM must be powered by dedicated power feeds derived from feed B.
  • Page 30 Figure 23: DC PSM Inputs Figure 24: Connecting the Positive DC Source Power Cable Lugs to a PSM 11. Connect the negative (–) DC source power cables to input 1 and input 2 –48V input terminals (Figure 23 on page 30 Figure 25 on page 31).
  • Page 31 Figure 25: Connecting the Negative DC Source Power Cable Lugs to a PSM 12. Verify that the source power cables are connected to the appropriate terminal: the positive (+) source cable to the return terminal (labeled RTN) and the negative (–) source cable to the input terminal (labeled –48V).
  • Page 32: Step 8: Power On The Ptx3000

    IN THIS SECTION Power On the AC-Powered PTX3000 | 32 Power On the DC-Powered PTX3000 | 34 To power on the PTX3000, perform one of the following procedures: Power On the AC-Powered PTX3000 To power on an AC-powered router: 1. Verify that each power supply module (PSM) is fully inserted in the chassis and that the captive screws on the PSM faceplates are tightened.
  • Page 33 9. Verify that the OK LED on the AC PSM faceplate is lit steadily, indicating that power supply is correctly installed, functioning properly, and providing power to the outputs. 10. On the external management device connected to the PTX3000, monitor the startup process to verify that the system has booted properly.
  • Page 34: Power On The Dc-Powered Ptx3000

    Power On the DC-Powered PTX3000 To power on a DC-powered PTX3000: NOTE: After powering off a power supply, you must wait at least 60 seconds before powering it on again. 1. Verify that the power supply modules (PSMs) are fully inserted in the chassis and that the captive screw on the faceplate of each PSM is tightened.
  • Page 35 If the OK LED is not light steadily, remove the PSM, repeat the cabling procedure, and reinstall the PSM into the PTX3000. 10. On the external management device connected to the PTX3000, monitor the startup process to verify that the system has booted properly.
  • Page 36: Step 9: Install The Front Doors On The Ptx3000

    Step 9: Install the Front Doors on the PTX3000 Front doors are installed over the card cage that contains the components in the chassis. Each PTX3000 is shipped with two front doors, one door for each card cage. Captive thumbscrews secure the door to the chassis.
  • Page 37: Step 10: Perform The Ptx3000 Initial Software Configuration

    Step 10: Perform the PTX3000 Initial Software Configuration These procedures connect a PTX3000 to the network but do not enable it to forward traffic. For complete information about enabling the PTX3000 to forward traffic, including examples, see the Junos OS configuration guides.
  • Page 38: Enter Configuration Mode

    Configure System Attributes | 39 Commit the Configuration | 40 Enter Configuration Mode 1. Verify that the network device is powered on. 2. Log in as the root user. There is no password. Amnesiac <ttyd0> login: root 3. Start the CLI. root@% cli root>...
  • Page 39: Configure System Attributes

    3. Set the user account class to super-user. [edit] root@host# set system login user user-name class super-user Configure System Attributes 1. Configure the name of the PTX3000. If the name includes spaces, enclose the name in quotation marks (“ ”). [edit] root@# set system host-name host-name NOTE: The DNS server does not use the hostname to resolve to the correct IP address.
  • Page 40: Commit The Configuration

    0 family inet address address/prefix-length 5. Configure the IP address of a backup router. The backup router allows the PTX3000 to install a route to the management network while the Routing Engine or RCB is booting and before the routing protocol process (rpd) is up and running.
  • Page 41 backup-router address; root-authentication { authentication-method (password | public-key); name-server { address; interfaces { em0 { unit 0 { family inet { address address/prefix-length; 2. Commit the configuration to activate it. [edit] root@# commit 3. Optionally, configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them.
  • Page 42: Safety Warnings

    Safety Warnings WARNING: See installation instructions before connecting the PTX3000. This is a summary of safety warnings. For a complete list of warnings for the PTX3000, including translations, see the PTX3000 Packet Transport Router Hardware Guide https://www.juniper.net/documentation/. WARNING: The intrabuilding ports of the equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only.
  • Page 43 Manually installing the PTX3000 without a mechanical lift is not supported. The PTX3000 must be mounted at the bottom of the rack if it is the only unit in the rack. When mounting the PTX3000 in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
  • Page 44: Ptx3000 Compliance Statements For Nebs

    The battery return connection is to be treated as an isolated DC return (DC-I), as defined in GR-1089-CORE. For Juniper systems with AC power supplies, an external surge protective device (SPD) must be used at the AC power source. Compliance Statements for EMC Requirements...
  • Page 45: Israel

    Israel Translation from Hebrew—Warning: This product is Class A. In residential environments, the product might cause radio interference, and in such a situation, the user might be required to take adequate measures. Japan The preceding translates as follows: This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI).
  • Page 46: Junos Os Documentation And Release Notes

    JTAC Hours of Operation —The JTAC centers have resources available 24 hours a day, 7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: https://www.juniper.net/customers/support/...
  • Page 47: Creating A Service Request With Jtac

    Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/ Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/ Create a service request online: https://myjuniper.juniper.net To verify service entitlement by product serial number, use our Serial Number Entitlement (SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/...
  • Page 48: Revision History

    Copyright © 2019 Juniper Networks, Inc. All rights reserved. Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. and/or its affiliates in the United States and other countries. All other trademarks may be property of their respective owners.