Installing a PTX5000 60-A DC PDU

290
Each PDU weighs approximately 60 lb (27.2 kg). The input power tray weighs 1.6 lb
(0.7 kg). To install a PDU:
Make sure that the voltage across the DC power source cable leads is 0 V and that
1.
there is no chance that the cables might become active during installation.
Verify that the input power switches on the PDU faceplate of the replacement PDU
2.
are in the
position (
OFF
Verify that the
LEDs on the PDU faceplate are off.
3.
DC IN
Remove the input power trays from the replacement PDU. Store the input power trays.
4.
Using both hands, slide the PDU into the chassis until you feel resistance (see
5.
Figure 166 on page
290).

Figure 166: Installing a 60-A DC PDU

Push the metal handle up toward the PDU.
6.
Tighten the captive screws on the metal handle. Use a Phillips (+) screwdriver.
7.
Slide the input power trays into the new PDU
8.
).
O
(Figure 167 on page
291).
Copyright © 2017, Juniper Networks, Inc.