PTX5000 Packet Transport Router Hardware Guide

Troubleshooting the PTX5000 FPCs

Problem
Solution
526
Replacing a PTX5000 Control Board on page 401
Description:
Alarms listed in
Table 92 on page 528
an FPC.
To troubleshoot an FPC:
Look at the display on the craft interface to check the status of the FPC and the PICs
1.
that are plugged into it.
Issue the
2.
show chassis alarms
user@host> show chassis alarms
2 alarms currently active
Alarm time
2012-11-02 17:46:53 PDT
Verify that the FPC is properly seated in the midplane. Check that each ejector handle
3.
has been turned clockwise and is tight. Use a screwdriver to check that the screws
inside the ejector handles are tight.
Check the status of an FPC using the following CLI command:
4.
user@host> show chassis fpc
Slot State
0
Online
1
Empty
2
Online
3
Online
4
Offline
5
Online
6
Online
7
Offline
To determine the cause of link errors between the FPCs and SIBs, use the
5.
command to check the status of the FPCs and SIBs.
fabric summary
user@host> show chassis fabric summary
FRU
State
SIB0
Online
SIB1
Online
SIB2
Online
SIB3
Empty
SIB4
Online
and
Table 93 on page 528
command.
Class
Description
Major
FPC 3 PIC 1 Failure
Temp
CPU Utilization (%)
(C)
Total
Interrupt
50
5
0
51
5
0
53
5
0
---Configured power off---
50
9
0
50
5
0
---No power---
Errors
None
None
None
None
indicate a problem with
Memory
Utilization (%)
DRAM (MB) Heap
Buffer
2816
7
2816
9
2816
7
2816
9
2816
7
show chassis