Maintaining the PTX5000 Control Boards

Purpose
Action
Related
Documentation

Maintaining the PTX5000 FPCs

Purpose
Action
Copyright © 2017, Juniper Networks, Inc.
Troubleshooting the PTX5000 Host Subsystem on page 520
Troubleshooting the PTX5000 Routing Engines on page 522
For optimum performance, verify the condition of the Control Boards.
On a regular basis:
Check the host subsystem LEDs on the craft interface. See
LEDs" on page
18.
During normal operations:
The green host subsystem
The red host subsystem
Look at the LEDs on the Control Board faceplates to see information about the Control
Boards.
During normal operations:
The green
OK
LED on the Control Board faceplate is lit.
The yellow
LED on the Control Board faceplate is not lit.
FAIL
Issue the
show chassis environment cb
operating properly.
PTX5000 Host Subsystem Description on page 75
PTX5000 Control Board LEDs on page 87
PTX5000 Control Board Description on page 83
Troubleshooting the PTX5000 Control Boards on page 524
For optimum packet transport router performance, verify the condition of the FPCs.
On a regular basis:
Check the LEDs on the FPC. During normal operation:
The green
OK
LED located the bottom of the FPC lights steadily when the FPC is online
and functioning normally. The green
Issue the CLI
show chassis fpc
value
in the column labeled
Online
LED on the craft interface is lit.
OK
LED on the craft interface is not lit.
FAIL
command to verify that the Control Boards are
LED blinks during startup.
OK
command to check the status of installed FPCs. The
indicates that the FPC is functioning normally.
State
Chapter 35: Maintaining Components
"PTX5000 Craft Interface
485