To install all eight FPC2-PTX-P1A FPCs, you must upgrade the
PDUs and PSMs with PDU2-PTX-DC and PSM2-PTX-DC, respectively.
Otherwise, you can only install a maximum of six FPC2-PTX-P1A FPCs.
Refer to
"Calculating PTX5000 Power Consumption" on page 123
more details.
The following components are required to upgrade the FPCs to FPC3-PTX-U2 in a
PTX5000:
FPC3-PTX-U2 FPCs
SIB3-PTX5K SIBs
FAN3-PTX-H fan tray
NOTE:
When upgrading to FPC3-PTX-U2 FPCs, you are not required to
upgrade to the PDU2-PTX-DC power distribution unit or the PSM2-PTX-DC
power supply module.
The following components are required to upgrade the FPCs to FPC3-PTX-U3 in a
PTX5000:
FPC3-PTX-U3 FPCs
SIB3-PTX5K SIBs
FAN3-PTX-H fan tray
PDU2-PTX-DC power distribution unit
PSM2-PTX-DC power supply module
NOTE:
PTX5K-PSM2TRAY is used only if you are upgrading the power
supplies to high capacity PDUs and PSMs.
NOTE:
The PTX5000 supports two midplanes. The FPC3-PTX-U3 FPC
must be installed in the PTX5000BASE2 model midplane.
Upgrading the FPCs in an Operational PTX5000 Packet Transport Router on page 458
Upgrading the FPCs in an Offline PTX5000 Packet Transport Router on page 468
Upgrading to the High Capacity DC Power System on page 373