Table 15: Dc Psms Supported On The Ptx5000 - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

PTX5000 Packet Transport Router Hardware Guide
40
Sixteen LEDs to monitor the status of the PDU—See
Unit LEDs" on page 56
for details.
Air exhaust ventilation
PTX5000 DC Power Supply Module
DC PSMs Supported on the PTX5000
The PTX5000 supports the DC power supply modules (PSMs) in

Table 15: DC PSMs Supported on the PTX5000

Name
DC PSM (120-A)
DC PSM (60-A)
High Capacity DC PSM (60-A)
PTX5000 Normal Capacity DC PSM
Figure 24 on page 41
shows both the normal-capacity 60-A DC PSM and 120-A DC PSM.
Each DC PSM weighs approximately 10.6 lb (4.8 kg).
CAUTION:
The 60-A DC PSM and 120-A DC PSM are not interchangeable.
The 60-A DC PSM must be installed in the 60-A DC PDU. The 120-A DC PSM
must be installed in the 120-A DC PDU. The faceplate of both DC PSM looks
the same. To avoid damaging the connectors on the back of the PSM or inside
the PDU, use caution to ensure that you have the correct PSM before installing
it in the PDU.
"PTX5000 Power Distribution
Model Number
PSM-PTX-DC-120
PSM-PTX-DC-60
PSM2-PTX-DC
Copyright © 2017, Juniper Networks, Inc.
Table 15 on page
40.
First Supported Junos OS
Release
12.1X48
12.3
12.1X48R3
12.3