up-count

Overview
This command sets the number of consecutive pings that the polling instance
must receive a reply to before classifying the device reachable again.
The no variant of this command resets the up count to the default of 30.
Syntax
up-count <1-100>
no up-count
Default
The default is 30.
Mode
Ping-Polling Configuration
Examples
To set the upcount to 5 consecutive pings for ping-polling instance 45, use the
commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
To reset the upcount to the default value of 30 consecutive pings for ping-polling
instance 45, use the commands:
awplus#
awplus(config)#
awplus(config-ping-poll)#
Related
critical-interval
Commands
fail-count
normal-interval
ping-poll
sample-size
show ping-poll
timeout (ping polling)
C613-50170-01 Rev B
Parameter
Description
<1-100>
Number of replied pings before an unreachable device is classified as
reachable.
configure terminal
ping-poll 45
configure terminal
ping-poll 45
Command Reference for x510 Series
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
up-count 5
no up-count