This example shows how to configure the TX power low warning threshold to 0.181 mW on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring tx-power eth3/0/1 low warning mwatt 0.181
WARNING: The closest value of 0.181 is chosen according to the transceiver-monitoring
precision definition
Switch(config)#
27-8 transceiver-monitoring voltage
This command is used to configure the threshold voltage of the specified port. Use the no form of the
command to remove the configuration.
transceiver-monitoring voltage INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring voltage INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE-ID
high
low
alarm
warning
VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for
this configuration.
This command configures the voltage thresholds on the specified port. The value will be stored both in
the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then written into
the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is just
stored in the system and the displayed value will be the user-configured threshold. If there is no user-
configured threshold, the displayed value will always reflect the factory preset value defined by the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+ transceivers. Use the no form of the command to prevent
threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Specifies the interface to modify.
Specifies that when the operating parameter rises above the highest
threshold, it indicates an abnormal status.
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold conditions.
Specifies the threshold value. This value must be between 0 and
6.5535 Volt.