DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Switch(config)#
27-7 transceiver-monitoring tx-power
This command is used to configure the output power threshold for the specified port. Use the no form of
the command to remove the configuration.
transceiver-monitoring tx-power INTERFACE-ID {high | low} {alarm | warning} {mwatt VALUE |
dbm VALUE}
no transceiver-monitoring tx-power INTERFACE-ID {high | low} {alarm | warning}
Parameters
high
low
alarm
warning
mwatt VALUE
dbm VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for
this configuration.
This command configures the TX power thresholds on the specified port. This value will be stored both in
the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then written into
the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is just
stored in the system and the displayed value will be the user-configured threshold. If there is no user-
configured threshold, the displayed value will always reflect the factory preset value defined by the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+ transceivers. Use the no form of the command to prevent
threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
Specifies the interface to modify.
Specifies that when the operating parameter rises above this high
threshold value, it indicates an abnormal status.
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
Specifies to configure the high and low warning threshold conditions.
Specifies the power threshold value in milliwatts. This value must be
between 0 and 6.5535.
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.