DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
transceiver-monitoring rx-power INTERFACE-ID {high | low} {alarm | warning} {mwatt VALUE |
dbm VALUE}
no transceiver-monitoring rx-power INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE ID
high
low
alarm
warning
mwatt VALUE
dbm VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for
this configuration.
This command configures the RX power thresholds on the specified port. This value will be stored both in
the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then written into
the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is just
stored in the system and the displayed value will be the user-configured threshold. If there is no user-
configured threshold, the displayed value will always reflect the factory preset value defined by the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+ transceivers. Use no form of the command to prevent
threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the RX power low warning threshold as 0.135 mW on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring rx-power eth3/0/1 low warning mwatt 0.135
WARNING: A closest value 0.135 is chosen according to the transceiver-monitoring
precision definition.
Switch(config)#
Specifies the interface to modify.
Specifies that when the operating parameter rises above the highest
threshold, it indicates an abnormal status
Specifies that when the operating parameter falls below the low
threshold this value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold conditions.
Specifies the power threshold value in milliwatts. This value must be
between 0 and 6.5535.
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.
411