D-Link DXS-3600 Series Reference Manual page 412

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
27-6 transceiver-monitoring temperature
This command is used to configure the temperature thresholds for the specified port. Use the no form of
the command to remove the configuration.
transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE ID
high
low
alarm
warning
VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for
this configuration.
This command configures the RX power thresholds on the specified port. This value will be stored both in
the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then written into
the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is just
stored in the system and the displayed value will be the user-configured threshold. If there is no user-
configured threshold, the displayed value will always reflect the factory preset value defined by the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+ transceivers. Use the no form of the command to prevent
threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the temperature high alarm threshold as 127.994 on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring temperature eth3/0/1 high alarm 127.994
WARNING: A closer value of 127.992 is chosen according to the transceiver-monitoring
precision definition
Specifies the interface to modify.
Specifies that when the operating parameter rises above this high
threshold value, it indicates an abnormal status.
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold conditions.
Specifies the threshold value. This value must be between -128 and
127.996 °C.
412

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxs-3600-32s

Table of Contents