Adjusting Knife Speed and Pressure Alarms

The knife alarm features in the HarvestTouch
specified range.
1. To set either of the the knife alarms, engage the header to
display header run screen 1, and then press KNIFE
SETTINGS icon (A).
2. To adjust the KNIFE SPEED ALARM set point, press
arrows (A) until the desired value is shown.
NOTE:
The knife speed alarm alerts the Operator when knife
speed drops below a specified percentage of preset knife
speed. In the example shown, the alarm will sound if knife
speed drops below 875 spm. The default is 70% and the
minimum value is 50%.
3. To adjust the KNIFE PRESSURE ALARM set point, press
arrows (A) until the desired value is shown.
NOTE:
The alarm will be set off more often at a lower setting and
less often at a higher setting. The factory setting is 230 bar
(3400 psi).
262171
OPERATION
Display can inform the Operator when knife speed or pressure exceed a
Figure 5.147: HarvestTouch
Run Screen
Figure 5.148: Knife Adjust Page
Figure 5.149: Knife Adjust Page
264
A
Display - Header
A
A
Revision A