ATTACHING HEADERS TO AND DETACHING HEADERS FROM WINDROWER
7. Select PLAY icon (A).
NOTE:
The PLAY icon will only appear if the header is engaged.
8. The calibration will attempt the first calibration stage.
NOTE:
Selecting X icon (A), HOME, or BACK, or pressing any of the
ground speed lever (GSL) buttons at any time during
calibration will EXIT the calibration process without saving
your progress. The engine speed will return to the original
rpm before starting the calibration process.
NOTE:
If a sensor goes out of its normal operating range during
the calibration process, calibration will stop and a message
will appear on the screen indicating that a sensor is out
of range.
9. When the first stage of the calibration is complete, select
PLAY icon (A) on the screen to continue with the second
stage of the calibration process.
262171
Figure 4.144: Engage Header Warning
Figure 4.145: Calibration Page