MacDon M2170NT Operator's Manual page 530

Windrower
Hide thumbs Also See for M2170NT:
Table of Contents

Advertisement

J1939
J1939
Telltale
SPN
FMI
Check
1388
3
Engine
Check
1388
4
Engine
Check
1388
14
Engine
Check
1569
31
Engine
Check
1639
0
Engine
Check
1639
1
Engine
Check
1639
2
Engine
Check
1639
15
Engine
Check
1639
17
Engine
Check
1668
2
Engine
Check
1675
31
Engine
1761
1
DEF
Check
1761
3
Engine
Check
1761
4
Engine
Check
1761
9
Engine
Check
1761
10
Engine
Check
1761
11
Engine
262171
REFERENCE
Cummins
Lamp
Fault Code
Auxiliary Pressure #2
297
Amber
Auxiliary Pressure #2
298
Amber
Auxiliary Pressure #2
6584
Amber
Engine Protection
Amber
3714
Torque Derate
Fan Speed
Amber
4789
Fan Speed
Amber
4791
Fan Speed
None
6469
None
Fan Speed
6467
Fan Speed
None
6468
J1939 Network #4 - Data
None
4437
erratic
Engine Starter Mode
None
3737
Aftertreatment 1 Diesel
Amber
1673
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
1669
Amber
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
Amber
1668
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
Amber
4677
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
4769
Amber
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
None
6562
Exhaust Fluid Tank Level
510
J1939_SPN Description
Detail
Auxiliary Pressure Sensor Input 2
Circuit - Voltage above normal, or
shorted to high source
Auxiliary Pressure Sensor Input 2
Circuit - Voltage below normal, or
shorted to low source
Auxiliary Pressure Sensor Input 2
- Special Instructions
Engine Protection Torque Derate
- Condition exists
Fan Speed - Data Valid but Above
Normal Operational Range - Most
Severe Level
Fan Speed - Data Valid but Below
Normal Operational Range - Most
Severe Level
Fan Speed – Data is erratic,
intermittent, or incorrect
Fan Speed - Data Valid but Above
Normal Operational Range - Most
Severe Level
Fan Speed - Data Valid but Below
Normal Operational Range - Most
Severe Level
J1939 Network #4 - Data is
erratic, intermittent, or incorrect
Engine Starter Mode Overcrank
Protection - Condition exists
Aftertreatment 1 Diesel Exhaust
Fluid Tank Level - Data valid but
below normal operational range -
Most Severe Level
Aftertreatment 1 Diesel Exhaust
Fluid Tank Level Sensor Circuit -
Voltage above normal, or shorted
to high source
Aftertreatment 1 Diesel Exhaust
Fluid Tank Level Sensor Circuit -
Voltage below normal, or shorted
to low source
SAE J1939 Multiplexing PGN
Timeout Error - Abnormal
update rate
Aftertreatment 1 Diesel Exhaust
Fluid Tank Level Sensor -
Abnormal rate of change
Aftertreatment 1 Diesel Exhaust
Fluid Tank Level Sensor - Root
cause not known
Revision A

Advertisement

Table of Contents
loading

Table of Contents