Digi IX30 hardware reference
RSSI > -80, bars=5
-90 < RSSI <= -80, bars=4
-100 < RSSI <= -90, bars=3
-106 < RSSI <= -100, bars=2
RSSI <= -106, if we're connected to the cellular network, bars=1, if not bars=0
bars is then reported as the signal strength bars.
2G algorithm
For 2G, the IX30 determines RSSI signal strength:
RSSI > -80, bars=5
-89 < RSSI <= -80, bars=4
-98 < RSSI <= -89, bars=3
-104 < RSSI <= -98, bars=2
RSSI <= -104, if we're connected to the cellular network, bars=1, if not bars=0
bars is then reported as the signal strength bars.
IX30 power supply requirements
IX30 is intended to be powered by a certified power supply with output rated at either 12 VDC/0.75 A
or 24 VDC/0.375 A minimum.
Use the power supply part number 24000154.
n
If you are providing the DC power source with a non-Digi power supply, you must use a
n
certified LPS power supply rated at either 12 VDC/0.75 A or 24 VDC/0.375 A minimum. The
voltage tolerance supports +/- 10% (9 VDC to 30 VDC) at 9 Watts minimum.
For installations requiring protective earth grounding, connect the -ve terminal of the power
n
connector to the system protective earth with a minimum 1mm2 stranded single insulated
cable. Crimp terminals should be used for all connections.
Digi IX30 serial connector pinout
The IX30 is a DTE serial device capable of supporting the RS-232, RS-422, or RS-485 electrical
signalling modes. The IX30 default setting RS-232 signaling.
Change the signalling mode
To change the signalling mode:
Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
2. Access the device configuration:
Remote Manager:
a. Locate your device as described in
device.
b. Click the Device ID.
IX30 User Guide
IX30 power supply requirements
Use Digi Remote Manager to view and manage your
28