Serial port
rs-232
n
rs-422
n
l
rs-485
n
l
The default is rs-232.
6. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
7. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate rate
(config)>
8. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>
9. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
10. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits bits
(config)>
11. Set the type of flow control used by the device to which you want to connect:
(config)>path-paramflow value
(config)>
where value is one of:
none
n
rts/cts
n
xon/xoff
n
IX30 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Enable termination if you want to enable electrical termination on this serial port:
(config)> serial port1 termination true
(config)>