Serial port
3. Click to expand the port that you want to configure for UDP serial mode.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select UDP serial.
The default is Remote.
5. (Optional) For Label, enter a label that will be used when referring to this port.
6. For Signalling, select the electrical signaling interface type used on this serial port:
RS-232
n
RS-422
n
l
RS-485
n
l
The default is RS-232.
7. Expand Serial Settings.
a. For Baud rate, select the baud rate used by the device to which you want to connect.
b. For Data bits, select the number of data bits used by the device to which you want to
connect.
c. For Parity, select the type of parity used by the device to which you want to connect.
d. For Stop bits, select the number of stop bits used by the device to which you want to
connect.
e. For Flow control, select the type of flow control used by the device to which you want to
connect.
IX30 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Enable Termination if you want to enable electrical termination on this serial port.