Serial port
1. Log into the IX30 WebUI as a user with Admin access.
2. On the menu, click System. Under Configuration, click Serial Configuration.
The Serial Configuration page is displayed.
Note
You can also configure the serial port by using Device Configuration > Serial. Changes
made by using either Device Configuration or Serial Configuration will be reflected in both.
3. Click the name of the port that you want to configure.
The serial port is enabled by default. To disable, toggle off Enable.
4. For Mode, select Application. The default is Remote.
5. (Optional) For Label, enter a label that will be used when referring to this port.
6. For Signalling, select the electrical signaling interface type used on this serial port:
RS-232
n
RS-422
n
l
RS-485
n
l
The default is RS-232.
7. Click Apply to save the configuration and apply the change.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
IX30 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Enable Termination if you want to enable electrical termination on this serial port.
Configure Application mode
230