Serial port
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. The serial port is enabled by default. To disable:
(config)> serial port1 enable false
(config)>
4. Set the mode:
(config)> serial port1 mode application
(config)>
5. Set the signaling interface type used on this serial port:
rs-232
n
rs-422
n
l
rs-485
n
l
The default is rs-232.
6. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure PPP dial-in mode

PPP dial-in allows the device to answer Point-to-Point Protocol (PPP) connections over serial ports.
To change the configuration to match the serial configuration of the device to which you want to
connect:
  Web
1. Log into Digi Remote Manager, or log into the local Web UI as a user with full Admin access
rights.
IX30 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Enable termination if you want to enable electrical termination on this serial port:
(config)> serial port1 termination true
(config)>
Configure PPP dial-in mode
231